MSA 2050 SSD read cache on controller B only 4% allocated
I have an issue on HPE MSA 2050 SAS storage pool B read cache. It has a RAID5 disk group and an SSD read cache. The volume assigned to is a storage for hyper-v virtual machines. The cache has 182214...
View ArticleEVA4400 Controller event log Binary Analysis method
Hello AllThis is 555-denoh.I have obtained the EVA4400 log file tmpScEventFile000001.idi.How can I analyze this log?Thank you for your advice.Thanks, Best Regards.
View ArticleRAID 6 Vdisk Offline - Unable to Add Spare Disk (HP MSA 2040 SAN)
I am experiencing an issue with the HP MSA 2040 SAN storage system. Currently, vdisk vd0001, which is configured as RAID 6, is showing a Fault status and is Offline. Below are the steps I have taken...
View ArticleMSA 2060 CSI driver
Hello, team!I understand that MSA Storage does not have native integration for Kubernetes. Is there a guide to install CSI driver via third party for MSA?
View ArticleMSA 2060 - REPLICATION ERROR
Hi , can anyone help me with this error we've encounter in creating a Replication in ""HPE MSA 2060"".We need some help to find the active remote port which we didn't create. Or help me understand what...
View ArticleMSA 2060 EOSL
MSA 2060 end of life and end of support. I would like to know these details
View ArticleMSA volume
Hi,I have a 1 volume created in MSA. Can I create multiple data stores when presenting this to the ESXi host?Thank you.
View ArticleMissing one parameter while using SMU to configure email on MSA...
Resolution for error indicating that the command is missing at least one parameter while configuring/reconfiguring email on MSA 1060/2060/2062 for firmware IN210P002 :When using the Storage Management...
View ArticleWhy Are My HPE MSA Storage Volumes Not Expanding After Adding More Drives?
Hi everyone,I’ve recently added more drives to my HPE MSA Storage system, but I’m running into an issue where the volumes are not expanding automatically to utilize the new drives. I’ve checked the...
View ArticleMSA 2070 LFF with expansion
Hi, I have a quick question about RAID configuration. Is it possible to create a RAID group (specifically MSA DP+) that spans multiple enclosures? In this case, there are two.For example, in an MSA...
View ArticleHow to Safely Remove a Disk from dgB01(MSA-DP+) and Clear Metadata on...
How to Safely Remove a Disk from dgB01 (MSA-DP+) and Clear Metadata on HPE MSA 2060 FC Without Data Loss?Hello HPE Community,I need assistance with safely removing a disk from a disk group (dgB01) on...
View ArticleMSA 2062 to MSA 2052 replication error
Hello!I am using replication between a MSA 2062 Fc and a MSA 2052 Fc and I am currently deleting old replication sets (I was used to have a set per volume and quickly lost overview) and creating new...
View ArticleHP MSA 2040 HD amber light
Hello, I am seeking advise on a HD LED light that is amber. I have a Seagate SAS MDL 3TB online led that is green, but the fault light is solid amber. I have ran the show cache-parameter and show...
View ArticleDisable MSA2060 Update Server
We have a standalone MSA2060 running the latest firmware. It is not connected to the internet. How would I disable the Update Server completely. The problem is I am getting alerts periodically...
View ArticleHPE Storage IntegrationPack 4VC 13.0
Estoy tratando de dar de alta un storage MSA 2060FC, dentro de la aplicacion, pero si bien me conecta al MSA, al momento de setear los permisos sobre el pool, da error de conectividad.Alguien lo pudo...
View ArticleReplication between MSA 1050 and 2070
Dear Team,Can MSA Remote Snap replicate volume form msa 1050 to MSA 2070 using either iscsi or FC protocal.I have read the MSA Remote Snap white paper, it does not specifically addres this...
View ArticleLEFTOVR_SAS_600.1GB 6.0 Degraded_The disk may contain invalid metadata. Disk...
Hello Team,After site cut over, i got the below error : Note : It's an HP MSA 2000 G3Should remove one disk and wait for rebuild ? or should i run "trust" command ?Awaiting for your feedback [Moderator...
View ArticleOIDs for Monitoring of MSA SAN 2060/2050
Hi There teamI have had an HP support case open for this, but they didn't resolve it. We use a product called Datto to monitor servers and san's. It is a standard SNMP based utility and they work fine...
View ArticleAllocated snapshot space exceeded the configured limit
Hello,We have 2 x MSA 2052 that replicates some volumes between them from primary DC to secondary DC.The problem is that at the time of replication we get the following error on the destination array:...